An important aspect of the discussion of loading protocols for dental implants was to define the terms to be used, since there has been confusion in the past over definitions of terms related to restoration. The group worked to clarify these. Notably, for immediate restoration it had not been defined whether the prosthesis is in contact with the opposingdentition; thus it was necessary to clarify the occlusal scheme used at the time of restoration.
According to the body of literature, in agreement with the previous (1997) ITI consensus, a minimum of 3 months of healing prior to implant loading had been established as conventional loading. However, the group felt that with increasing evidence to support reduced healing times for rough-surfaced titanium implants, the definition of conventional healing periods for these implants might be modified.
Most of these terms were recently defined in a conference on immediate and early loading that occurred in Spain in May 2002(1). However, the group modified these definitions for use in this report. The modified definitions are presented here:
Review of Loading Protocols
Changes in loading protocols are not uncommon in implant dentistry. Early work focused on the predictability of osseointegration, predominantly in edentulous mandibles. Subsequent work focused on implant integration in partially edentulous patients and various clinical indications. More recent studies have been directed at achieving quicker integration and shorter healing periods prior to implant restoration. More rapid integration has been attempted by modifying the titanium implant surface and by stimulating the surrounding tissues with growth-promoting substances such as bone grafts and growth factors. The ultimate loading protocol is immediate: providing the patient with a tooth replacement the day the implant is placed. Loading protocols can best be interpreted on the biologic basis of implant integration.
The process involved in the osseointegration of dental implants is poorly understood. Many professionals do not appreciate the fact that osseointegration is instantaneous. Osseointegration is defined as bone-to-implant contact at the light microscopic level. As soon as an implant is placed into the jawbone, certain areas of the implant surface are in direct contact with bone, ie, osseointegrated. Cochran and coworkers(2) have described this as primary bone contact. With the ITI Dental Implant System (Institut Straumann), the instrumentation is designed such that the osteotomy preparation has a slightly smaller diameter than the implant, so that the implant has a “press-fit” against the bone tissue. This represents the predominant contact with the bone at early healing times. As healing occurs, however, this bone is remodeled, and areas of new bone contact with the implant surface appear (particularly with more osteoconductive surfaces such as the SLA [sandblasted, large-grit, acid-etched; Institut Straumann]). This remodeled bone and new bone contact, termed secondary bone contact, predominates at later healing times when the amount of primary contact is decreased. By understanding these concepts one can appreciate how various loading protocols are possible and can view loading protocols as dependent on 2 distinct processes.
Immediate loading protocols were first described for the completely edentulous mandible. This indication is dependent on existing bone at the implant site. In the completely edentulous anterior mandible, where bone is typically extremely dense, large amounts of primary bone contact occur. Thus, instantaneous osseointegration occurs in large amounts of cortical bone, giving the implant immediate stability. Combined with a rigid connection of the implants, this provides for stability of the entire complex and osseous healing around the implants, ie, clinical implant success. It is not surprising, then, that immediate loading of multiple implants in the edentulous mandible can be a very successful procedure. This represents one scenario for the early/immediate loading of implants and is dependent on the existing quality and quantity of osseous tissue.
Another scenario with implications for early/immediate loading protocols is dependent not only on the existing bone quality and quantity but also on the possibility of rapid formation of bone tissue around the implant. This scenario occurs in indications where the quality and quantity of bone are not ideal, eg, sites with minimal cortical (dense) bone. In these cases, the ability to stimulate bone formation becomes crucial. Thus, early loading protocols become feasible and immediate loading protocols become less likely. The use of implants with modified surfaces that increase bone-to-implant contact and removal torque values has allowed shortened healing times under these conditions. For example, Cochran and coworkers(3) have demonstrated that implants with an SLA surface placed in areas of typically lower-quality bone can be restored after just 6 weeks of healing (early loading).
This analysis suggests that shortened loading protocols should focus on
In addition, 2 general scenarios are possible that relate to mechanisms of implant support that allow for reduced healing times. When existing bone of high quality and quantity is found, immediate loading of the implant may be possible. If the existing bone is not of high quality and quantity, then bone formation must occur in a relatively short time so that early loading of the implants can take place.
Various loading protocols for the restoration of dental implants are described in the literature. Several terms are important to understand when discussing them. In the case of direct occlusal contact, the restoration makes contact with the opposing dentition. With indirect occlusion, the implant is restored without directly contacting the opposing dentition, ie, it is out of occlusion. With progressive loading, the implant is restored in “light” contact initially and is gradually brought into full contact with the opposing dentition. Unfortunately, it is currently unknown whether the type of occlusion has an influence on the success of the timing of loading of the implant.
Another important aspect of loading protocols is the implant site. The site can range from a wellhealed edentulous space to an area where a tooth has just been removed - an immediate extraction site. In the latter case, the size of the defect around the implant varies depending on the size of the tooth being extracted. Another section of this consensus conference addressed the placement of implants in extraction sites; however, it is clear that the nature of the implant site can have a significant impact on the outcome of the implant restoration, regardless of the loading protocol. Thus, for the purpose of these reviews, when discussing implant loading protocols it was assumed that the implant is placed in a well-healed edentulous ridge with native bone surrounding the implant.
References:
(1) Aparicio C, Rangert B, Sennerby L. Immediate/early loading of dental implants: A report from the Sociedad Espanola de Implantes World Congress consensus meeting inBarcelona, Spain, 2002. Clin Implant Dent Relat Res 2003;5:57–60.
(2) Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res 1998;40:1–11.
(3) Cochran DL, Buser D, ten Bruggenkate CM, et al. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;13:144–153.
An appreciation of the mechanism governing how an implant interacts with bone tissue provides a basis for understanding how immediate and early loading protocols are possible. Stability of the implant is important for the success of any loading protocol. In fact, the outcome most often assessed and most often associated with procedure success in the literature was implant stability, and in many citations it was the only outcome assessed. Stability of the implant was found to be influenced by factors including, but not limited to, implant surface and geometry, quality and quantity of bone, splinting of implants, control of occlusal load, and absence of detrimental patient habits.
The literature is often characterized by inclusion and exclusion criteria that limit evaluation to a selected patient population. Thus, the results are often obtained under conditions that are considered favorable. With the understanding that the literature base is small, and the strength of evidence is graded as inadequate to fair, the group reached the following conclusions.
Edentulous Mandible
In edentulous mandibles, the immediate loading of 4 implants with an overdenture in the interforaminal area with rigid bar fixation and cross-arch stabilization is a predictable and well-documented procedure. This indication represents the only indication where the literature includes randomized and controlled studies. According to criteria agreed upon by this consensus group, this procedure is supported by 7 studies involving 376 patients and 1,529 implants.
In contrast, the early loading of implants (splinted or unsplinted) in the edentulous mandible with an overdenture is not well documented. Only 6 publications considered by this consensus group support such a procedure. They involved just 85 patients and 230 implants.
Immediate loading of implants supporting fixed restorations in the edentulous mandible is a predictable and well-documented procedure, provided that a relatively large number of implants are placed. The consensus group considered the procedure to be supported by 15 articles involving 387 patients and 2,088 implants, 1,804 of which were immediately loaded.
The consensus group found only 6 publications supporting the early loading of implants in the edentulous mandible with a fixed restoration. The publications involved 51 patients and 272 implants, 234 of which were loaded early.
Edentulous Maxilla
No articles were found supporting immediate or early loading of implants with an overdenture in the edentulous maxilla. Therefore, this procedure would have to be considered experimental at this time.
In the edentulous maxilla, immediate or early loading of implants utilizing a fixed prosthesis is not well documented. Regarding immediate loading, 7 publications involving 30 patients and 276 implants were found and discussed by the consensus group. For early loading, 4 articles involving 26 patients and 192 implants were reviewed.
Partially Edentulous Mandible or Maxilla
In the partially dentate maxilla and mandible, the immediate restoration or loading of implants supporting fixed prostheses is not well documented. It should be noted that in many of these cases the restoration is not in contact with the opposing dentition. This observation highlights the care that must be expended to plan and successfully complete such a restoration. Factors that have been highlighted include the absence of parafunctional habits, the use of a roughened implant surface, the use of a threaded implant, and primary stability of the implant.
In contrast, the early restoration or loading of titanium implants with a roughened surface supporting fixed prostheses after 6 to 8 weeks of healing is well documented and predictable in the partially dentate maxilla and mandible. Results seem to indicate that the outcome is similar to results obtained with conventional procedures. However, because of the limited number of implants placed (in comparison to the number of conventionally loaded implants) and the short follow-up period, further studies are necessary before these procedures can be proposed as routine.
Interproximal crestal bone levels and soft tissue changes adjacent to immediately restored or loaded implants were found to be similar to those reported for conventional loading protocols. Other issues that were discussed included the following:
The following types of treatment are recommended, provided that all other aspects of diagnosis and treatment planning have been performed and considered acceptable by the clinician. Immediate restoration and loading procedures are considered to be advanced or complex. As such, it is assumed that the clinician has the required level of skill and experience. The recommendations are based on the literature and the collective experience of the consensus working group.
Immediate Restoration or Loading
Early Restoration or Loading
Conclusion
Consideration should be given to the quality of available evidence for these procedures. It is recognized that many of the clinical recommendations suggested by the consensus group are not yet associated with strong evidence. Readers should note that the experience of the group was used in formulating the recommendations.
Additional outcomes to be evaluated in future studies include:
References:
(1) Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark P-I, Zarb GA, Albrektsson T (eds). Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry.Chicago: Quintessence, 1985:199–209.
Download the QR code with a link to this page and use it in your presentations or share it on social media.
Download QR code